The content of the article:
Troubleshooting
Having detected a failure in the operation of any blocks, the device displays an error code on the display. If the problem is serious, as a rule, the air conditioner stops working. If more than one failure is detected at the same time, the most serious one is displayed on the scoreboard.
Error codes for VECO air conditioners of types BKL INV and BKC INV
VECO air conditioner error code | Decryption |
E1 | Failure of the indoor unit temperature sensor |
E2 error conditioners Veko | Evaporator temperature sensor malfunction |
E3 | Compressor malfunction |
E5 | No communication between indoor and outdoor modules |
1E errors of Veko conditioners | Outside temperature sensor violation |
2E | Capacitor temperature sensor failure |
Error codes for VEKO air conditioners of types AKH, BKH, AKP, BS, BKP, AS
VECO air conditioner error | Decryption |
Ff03 | Condenser overheating, cold option |
FF04 error code air conditioning Beko | Condenser overheating, heat option |
Ff06 | Indoor fan function failed |
Ff07 | Room temperature sensor malfunctioning |
FF08 error code air conditioning Beko | The evaporator temperature sensor is malfunctioning |
Ff09 | The condenser temperature sensor is malfunctioning |
Error codes for VECO air conditioners type BKN and AKN
Beko air conditioner error | RANNING indicator | SLEEPING indicator | TIMER indicator |
Solenoid type temperature sensor function malfunction | Blinks | Blinks | Blinks |
Room temperature sensor malfunction | Blinks | Blinks | Shines without a break |
Outside function of solenoid temperature sensor outside | Blinks | Blinks | Disconnected |
Indoor fan motor function failed | blinks | Shines without a break | Blinks |
Any of the above air conditioner errors Beko causes immediate disconnection of the device.
The most common malfunctions in the operation of air conditioners and the reaction of the system to their occurrence:
- The secondary start of the compressor is delayed for 3 minutes;
- If the top temperature of the compressor is more than 115 degrees, it stops working. The normal operating temperature is one hundred degrees;
- If the voltage level in the network is less than 175 or more than 260 Volts, the equipment is turned off;
- If the inverter overheats, too much current or high voltage is supplied to it, the system turns it off;
- If the electrical wires are disconnected in any of the blocks, the air conditioner stops;
- If the fan runs weaker or more intense than the norm (norm 300 - 400 rpm), the air conditioner is turned off;
- If for four minutes the system does not receive messages about the transition through "0", it turns off.