Error codes for air conditioners Beko (Veko, Beko) - decryption and instructions

Troubleshooting

Having detected a failure in the operation of any blocks, the device displays an error code on the display. If the problem is serious, as a rule, the air conditioner stops working. If more than one failure is detected at the same time, the most serious one is displayed on the scoreboard.

Error codes for VECO air conditioners of types BKL INV and BKC INV

VECO air conditioner error code Decryption
E1 Failure of the indoor unit temperature sensor
E2 error conditioners Veko Evaporator temperature sensor malfunction
E3 Compressor malfunction
E5 No communication between indoor and outdoor modules
1E errors of Veko conditioners Outside temperature sensor violation
2E Capacitor temperature sensor failure

Error codes for VEKO air conditioners of types AKH, BKH, AKP, BS, BKP, AS

VECO air conditioner error Decryption
Ff03 Condenser overheating, cold option
FF04 error code air conditioning Beko Condenser overheating, heat option
Ff06 Indoor fan function failed
Ff07 Room temperature sensor malfunctioning
FF08 error code air conditioning Beko The evaporator temperature sensor is malfunctioning
Ff09 The condenser temperature sensor is malfunctioning

Error codes for VECO air conditioners type BKN and AKN

Beko air conditioner error RANNING indicator SLEEPING indicator TIMER indicator
Solenoid type temperature sensor function malfunction Blinks Blinks Blinks
Room temperature sensor malfunction Blinks Blinks Shines without a break
Outside function of solenoid temperature sensor outside Blinks Blinks Disconnected
Indoor fan motor function failed blinks Shines without a break Blinks

Any of the above air conditioner errors Beko causes immediate disconnection of the device.

Error codes for air conditioners Beko (Veko, Beko) - decryption and instructionsThe most common malfunctions in the operation of air conditioners and the reaction of the system to their occurrence:

  • The secondary start of the compressor is delayed for 3 minutes;
  • If the top temperature of the compressor is more than 115 degrees, it stops working. The normal operating temperature is one hundred degrees;
  • If the voltage level in the network is less than 175 or more than 260 Volts, the equipment is turned off;
  • If the inverter overheats, too much current or high voltage is supplied to it, the system turns it off;
  • If the electrical wires are disconnected in any of the blocks, the air conditioner stops;
  • If the fan runs weaker or more intense than the norm (norm 300 - 400 rpm), the air conditioner is turned off;
  • If for four minutes the system does not receive messages about the transition through "0", it turns off.

Heating

Ventilation

Sewerage