The content of the article:
Most air conditioner models Chigo equipped with the option of self-diagnosis of malfunctions. When a malfunction is detected, the air conditioner stops and the Chigo air conditioner error code is displayed immediately, which can be easily found in the instructions.
For error reporting, air conditioners use blinking diodes located on the front of the indoor unit. When a breakdown of the air conditioner is detected, the bulbs begin to blink or glow continuously, which is also reflected in the instructions.
Error codes for CHIGO air conditioners
Chigo Air Conditioner Error | Decryption |
E0 | Power failure due to error |
E1 | Overpressure protection too weak |
E2 | Faulty indoor temperature sensor |
E3 | Faulty external temperature sensor |
E7 | The system is disconnected due to a voltage drop in the network |
E8 | Outdoor unit icing |
Indoor unit error codes
Decryption | Running indicator | Timer indicator | Chigo Air Conditioner Error Code |
The function of the internal temperature sensor is broken | 1 time in 8 seconds | + | E2 |
The function of the temperature sensor of the outdoor unit evaporator is impaired | 2 times in 8 seconds | + | E3 |
Icing protection | 3 times in 8 seconds | + | E8 |
The drain pump does not work | 4 times in 8 seconds | + | E9 |
Indoor fan does not work | 6 times in 8 seconds | + | E5 |
Outdoor unit check valve does not work | 7 times in 8 seconds | + | E7 |
Zero crossing error | + | 3 times in 8 seconds | E0 |
The temperature sensor of the internal evaporator does not work | + | 4 times in 8 seconds | E1 |
EEPROM crash | + | 6 times in 8 seconds | E6 |
Outdoor unit error codes
Decoding error conditioner CHIGO | Running indicator | Timer indicator | Chigo Air Conditioner Error Code |
Outdoor unit temperature sensor does not work | + | Blinks 1 time in 8 seconds | E2 |
Outdoor unit evaporator temperature sensor not working | + | Blinks 2 times in 8 seconds | E3 |
Compressor Current Protection | + | Blinks 3 times in 8 seconds | E7 |
The output temperature sensor does not work | + | Blinks 4 times in 8 seconds | E1 |
Failure to connect the outdoor and indoor units | + | Blinks 6 times in 8 seconds | E6 |
Module protection | + | Blinks 7 times in 8 seconds | E5 |
Decoding error conditioner CHIGO | Air conditioner error code CHIGO |
Defrost | Blinks 1 time in 1 second |
Outdoor unit icing protection | Blinks once every 3 seconds |
Room temperature sensor malfunctioning | Blinks 2 times in 4 seconds |
Thermal sensor malfunction on the indoor unit evaporator | Blinks 3 times in 5 seconds |
Malfunctioning outdoor unit | Blinks 4 times in 6 seconds |
Outdoor unit frost protection | Blinks 5 times in 7 seconds |
Pressure drop protection | Blinks 6 times in 8 seconds |
Outdoor fan is malfunctioning | Blinks 7 times in 9 seconds |
Overheat protection enabled | Blinks 8 times in 10 seconds |
Disturbed drain pump or drain | Blinks 9 times in 11 seconds |