Error codes for air conditioners CHIGO (Chigo) - decryption and instructions

Error codes for air conditioners CHIGO (Chigo) - decryption and instructionsMost air conditioner models Chigo equipped with the option of self-diagnosis of malfunctions. When a malfunction is detected, the air conditioner stops and the Chigo air conditioner error code is displayed immediately, which can be easily found in the instructions.

For error reporting, air conditioners use blinking diodes located on the front of the indoor unit. When a breakdown of the air conditioner is detected, the bulbs begin to blink or glow continuously, which is also reflected in the instructions.

Error codes for CHIGO air conditioners

Chigo Air Conditioner Error Decryption
E0 Power failure due to error
E1 Overpressure protection too weak
E2 Faulty indoor temperature sensor
E3 Faulty external temperature sensor
E7 The system is disconnected due to a voltage drop in the network
E8 Outdoor unit icing

Indoor unit error codes

Decryption Running indicator Timer indicator Chigo Air Conditioner Error Code
The function of the internal temperature sensor is broken 1 time in 8 seconds + E2
The function of the temperature sensor of the outdoor unit evaporator is impaired 2 times in 8 seconds + E3
Icing protection 3 times in 8 seconds + E8
The drain pump does not work 4 times in 8 seconds + E9
Indoor fan does not work 6 times in 8 seconds + E5
Outdoor unit check valve does not work 7 times in 8 seconds + E7
Zero crossing error + 3 times in 8 seconds E0
The temperature sensor of the internal evaporator does not work + 4 times in 8 seconds E1
EEPROM crash + 6 times in 8 seconds E6

Outdoor unit error codes

Decoding error conditioner CHIGO Running indicator Timer indicator Chigo Air Conditioner Error Code
Outdoor unit temperature sensor does not work + Blinks 1 time in 8 seconds E2
Outdoor unit evaporator temperature sensor not working + Blinks 2 times in 8 seconds E3
Compressor Current Protection + Blinks 3 times in 8 seconds E7
The output temperature sensor does not work + Blinks 4 times in 8 seconds E1
Failure to connect the outdoor and indoor units + Blinks 6 times in 8 seconds E6
Module protection + Blinks 7 times in 8 seconds E5
Decoding error conditioner CHIGO Air conditioner error code CHIGO
Defrost Blinks 1 time in 1 second
Outdoor unit icing protection Blinks once every 3 seconds
Room temperature sensor malfunctioning Blinks 2 times in 4 seconds
Thermal sensor malfunction on the indoor unit evaporator Blinks 3 times in 5 seconds
Malfunctioning outdoor unit Blinks 4 times in 6 seconds
Outdoor unit frost protection Blinks 5 times in 7 seconds
Pressure drop protection Blinks 6 times in 8 seconds
Outdoor fan is malfunctioning Blinks 7 times in 9 seconds
Overheat protection enabled Blinks 8 times in 10 seconds
Disturbed drain pump or drain Blinks 9 times in 11 seconds

Heating

Ventilation

Sewerage