The content of the article:
If EE blinks on the remote control, this indicates a Fuji air conditioner error. To start the self-test mode, simultaneously press and hold the SET TIME and TEMP \ DAY buttons for longer than 3 seconds. Error codes for Fuji air conditioners will be displayed.
Error codes for air conditioners Fuji
Error Code Air Conditioner Fuji | Deciphering the error code of the Fuji air conditioner |
E 00 | Error communicating remote control with indoor unit |
E 01 | Communication error between indoor unit and outdoor unit |
E 02 | The function of the room temperature sensor is impaired |
E 03 | Short circuit at room temperature sensor |
E 04 Fuji air conditioning errors | The function of the temperature sensor on the internal heat exchanger is impaired |
E 05 | Short circuit on the temperature sensor of the internal heat exchanger |
E 06 | The function of the temperature sensor of the outdoor heat exchanger is impaired |
E 07 | Short circuit on the temperature sensor of the outdoor heat exchanger |
E 08 | Disruption in the supply of electric current |
E 09 | Condensate collection tank full |
E 0R | Outdoor unit temperature sensor not responding |
E 0b | Short circuit on outdoor unit temperature sensor |
E 0C | It is necessary to open the temperature sensor on the drain pipe. |
E 0d | Short circuit on the drain pipe temperature sensor |
E 0E | System pressure too high |
E 0F | Too high or low outlet temperature |
E 11 | The control board does not work correctly |
E 12 Air Conditioner Errors Fuji | Indoor fan malfunction |
E 13 | The system gives incorrect signals |
E 14 | EEPROM violation |
Outdoor unit errors
If the outdoor temperature decreases, the fans of the outdoor unit can switch to a lower speed or operate intermittently.
Fuji air conditioner error code: Heat & Coolmodel - indicates the reverse cycle.
Air Conditioner Error Fuji | Diode 1 | Diode 2 | Diode 3 | Diode 4 | Diode 5 | Diode 6 |
No communication with indoor unit | – | – | x | 0 | x | x |
Indoor Unit Failure | – | – | x | x | 0 | x |
Condensate drain broken | – | – | x | x | x | 0 |
External heat exchanger temperature higher or lower than standard | – | – | x | x | 0 | 0 |
Abnormal outdoor temperature | – | – | x | 0 | x | 0 |
No power | – | – | 0 | x | x | x |
EEPROM fault error code Fuji air conditioning | – | – | 0 | 0 | 0 | 0 |
00 | 00 | 00 | 00 | 00 | 00 | |
Too high pressure | x | – | – | – | – | – |
Condensate drain system temperature broken | – | 0 | – | – | – | – |
0 - blinks every 0.5 seconds, 00 - blinks every 0.1 second, X - does not light.
Some errors from Fuji air conditioners are best handled by the wizard from the service center!