Decoding and designation of errors of Kentatsu conditioners

KSRU \ KSFU Series Error Codes

Air Conditioner Error Codes Kentatsu for models: KSRU70HFAN1, KSFU70XFAN1, KSFU120XFAN3, KSRU120HFAN3

Kentatsu Air Conditioner Error Error decoding
E1 There is no contact with the air temperature sensor in the indoor unit
E2 No contact with evaporator temperature sensor
E3 No contact with condenser temperature sensor
E4 There is no contact with the outdoor air temperature sensor
E5 There is no contact between the outdoor and indoor modules
E6 Prevention of overheating / freezing of the outdoor unit
E10 Compressor Pressure Failure
E13 The wires supplying electricity to the compressor are mixed up.
E14 Electricity is being supplied to the wrong phase.
P4 Evaporator Overheat Prevention
P5 Condenser Overheat Prevention
P7 The compressor is turned off in automatic mode due to a rise in temperature to the limit
P9 Includes frost protection
P10 Invalid outlet air pressure
P11 Air is sucked in at a pressure not specified by the manufacturer.
P12 Too high voltage is applied to the air conditioner
Hs Thawing outdoor unit

KSGH \ KSRH Series Error Codes

Error codes for models KSGH / KSRH53CFDN1, KSGH / KSRH21CFDN1, KSGH / KSRH53HFDN1, KSGH / KSRH35HFDN1, KSGH / KSRH26CFDN1.

Air Conditioner Error Code Kentatsu Error decoding
E1 EERPOM crash
E2 Zero Loop Transformation Failure
E3 Fan turns too fast or slow
E4 Compressor shut off due to too high voltage
E5 Lost Communication With Air Temperature Sensor Inside
E6 Lost Communication With Evaporator Temperature Sensor

Error code Kentatsu air conditioning for KSFU / KSRU140HFDN3 and KSFU / KSRU76HFDN3 models

Kentatsu Air Conditioner Error Decoding errors air conditioner Kentatsu
P4 Protection against overheating of the evaporator located in the indoor unit
P5 Outdoor unit capacitor overheat protection
P9 Thawing
E1 No voltage to temperature sensors
E2 No communication with evaporator temperature sensor
E3 No contact with condenser temperature sensor
E6 External module breakage warning

Error codes for duct type air conditioners

Mistakes Decryption
E0 Damage to the room temperature sensor
E1 Evaporator temperature sensor breakdown
E2 Damage to the temperature sensor of the external module
E3 No communication with outdoor unit
E4 Damage to the condensate pump
E5 EEPROM crash
E6 Condensate drain pan full