Decoding and instructions for error codes of air conditioners Lessar (Lessar)

Lessar air conditioners are equipped with an automatic troubleshooting function. Having detected a problem, the system issues an error code for the Lessar air conditioner on the front panel of the indoor unit. The error code is a special combination of flashing LEDs. An air conditioner error Lessar is displayed until measures are taken to eliminate it.

Error codes for Lessar air conditioners in cold mode

Air conditioner Lessar Diode Work Diode Timer
For one minute, the indoor fan does not work blinks
The power supply to the evaporator temperature sensor or the room temperature is interrupted blinks burns
Unacceptable voltage was applied to the compressor four times in a row blinks
Less air conditioner error: central control board failure blinks blinks
ROM failure burns blinks

Error codes for Lessar air conditioners in warm mode

Air conditioner error Lessar Diode Defrost Diode Work Diode Timer
An invalid voltage was applied to the compressor four times blinks blinks
Air conditioner error Lessar: for one minute the fan of the indoor unit does not work blinks blinks
No voltage or short circuit on the evaporator sensor blinks
The power supply to the room temperature sensor is interrupted blinks
Central Board Failure blinks blinks
ROM failure burns blinks

What to do if, after power is supplied, the device does not turn on and no air conditioner error codes are lit Lessar:

  • Verify fuse integrity;
  • Make sure that 220 volts are supplied to the air conditioner. If there is no power transformer on the primary winding, the board of the indoor module should be replaced. If the voltage is normal, the secondary winding should be checked. If the result is positive, it is necessary to change the board of the internal module. If negative, make sure that there is 14.5 volts at the transformer output. If the answer is no, the transformer should be changed.

If, after power is supplied, the Operation indicator is off, the Timer indicator blinks:

  • Put another control board. If this does not help, you should change the internal module board. If it helps, then the voltage is low in the network.

If the Work indicator is on, the Timer indicator is blinking, it means the EEPROM is faulty, to eliminate this error of the Lessar air conditioner, it is necessary to change the PCB board.