Error codes for air conditioners Pioneer (Pioneer) - decryption and instructions

Error codes for air conditioners Pioneer (Pioneer) - decryption and instructionsTo detect failures in the Pioneer air conditioning system, there is a self-diagnosis function. Error codes for Pioneer air conditioners are displayed using various combinations of multi-colored LEDs located on the front panel of the indoor unit. If at the same time the system has detected several faults, the codes are displayed in turn.

Air Conditioner Errors Pioneer indoor unit

Air conditioner error code Pioneer Yellow diode Green diode

Red diode

Decoding error conditioner Pioneer
E0 * Discharged temperature sensor function
E6 * The function of the condenser temperature sensor is broken
E6 * The function of the air temperature sensor on the street is broken
E1 * The function of the temperature sensor in the room is broken
E2 * The function of the evaporator temperature sensor is impaired
E3 m m m Broken indoor unit fan
E4 m * IPM system failure
E5 m m Power Outage
E8 * m m Power failure
E9 m Compressor started up incorrectly
EA * Invalid communication with the outdoor module
The EU m * Unacceptable electrical current is supplied to the air conditioner
HER EEPROM crash
EP No communication between external and internal modules
P0 The unit started working incorrectly
P1 Discharge overheating
P2 Increased current in the circuit
P3 Mains voltage too high
P4 m m * No connection to current relay
P5 Evaporator Overheat
P6 Condenser overheating
P7 IPM matrix protection

*- the diode is lit, m - the diode blinks.

Error Codes for Pioneer Air Conditioners External Module

There is a red LED on the outdoor unit, which in a normal situation blinks this way: once from the side ON, once from the side OFF. If a malfunction is detected, the diode blinks twice from the OFF side and three times from the ON side.

After that, the frequency of blinks increases, and their mode will correspond to the error code of the air conditioner Pioneer.

Pioneer air conditioner error code (diode blinks) Air conditioner error decoding Pioneer
1 No connection to external temperature sensor
2 No connection to condenser temperature sensor
3 No connection with discharge temperature sensor
4 Mains current too high
5 Mains voltage too high
7 No communication with indoor unit
9 The unit is not started up correctly
12 Mains voltage exceeded
13 IPM Protection
16 Compressor temperature rise
17 Discharge temperature too high
18 Condenser temperature too high
19 IPM Card Failure
20 Failure in communication between indoor and outdoor modules
22 De-icing

Heating

Ventilation

Sewerage