Error codes for Toshiba air conditioners (Toshiba) - decryption and instructions

Air Conditioner Error Codes Toshibadisplayed on the scoreboard of the indoor unit.

The letter begins with E

Toshiba Air Conditioner Error Code Decryption error code Toshiba air conditioner
Literal meaning of Toshiba air conditioner error codes Toshiba Air Conditioner Error Code Numeric
E 01 There is no communication between the indoor unit and the remote control
E 02 Invalid data comes from the remote control
E 03 There is no communication between the indoor unit and the remote control
E 04 Toshiba air conditioner error code No communication between indoor and outdoor modules
E 06 No electric current is flowing to the internal module, board failure is possible, contact between the modules is broken
E 07 Broken temperature sensor SW30-2
E 08 Module addresses are not correctly transmitted
E 09 The remote control is broken
E 10 Broken internal module board
E 12 errors of Toshiba air conditioners The data in the external module is not correctly transmitted
E 15 The function of the internal module board is broken, the electric current is not correctly supplied
E 16 Outdoor module circuit breakdown
E 18 No batteries are inserted in the remote control or the internal module board is broken
E 19 Board breakage or no contact between modules
E 20 The address in the settings is broken
E 23 Incorrectly connected freon piping
E 25 No external module address
E 26 No contact with external module
E 28 Toshiba Air Conditioner Error Codes External modules are not connected correctly
E 31 Information on the boards of the external module does not pass correctly, breakdown of the boards

The letter designation begins with F, H, L

The literal value of the error code The numerical value of the error code Error Code Decryption
F 01 TCJ sensor broken
F 02 TC2 sensor not connected correctly
F 03 TC1 sensor not connected correctly
F 04 TD1 sensor not connected correctly
F 05 TD 2 sensor not working correctly
F 06 Sensor TE1 does not work correctly
F 07 The TL sensor does not work correctly
F 08 The maintenance sensor does not work correctly
F 10 TA sensor does not work correctly
F 12 Vehicle sensor 1 does not work correctly
F 13 IGBT Power Module Failure
F 15 Crash in TL, TE sensors
F 16 The function of the resistance sensors Ps, Pd
F 23 The function of the sensors Ps, Pd, 4-way valve is broken
F 24 High pressure sensor does not work correctly
F 29 EEPROM crash
F 31 Power failure
H 01 Inadmissible voltage is applied to the device
H 02 Phase failure
H 03 The power sensor is malfunctioning
H 04 Compressor malfunctioning, insufficient refrigerant
H 06 Invalid system pressure
H 07 Lack of oil in the system
H 08 Oil temperature increased
H 14 Compressor failure
H 16 Short circuit on oil sensor
L 03 The address of the external module is not correctly registered
L 04 Addresses are not registered correctly